| Signal Inputs |
Range |
Typical Transducer measuring range |
Inlet Manifold Pressure
(A pneumatic signal) |
0 to 250 Kpa Absolute |
|
| Storage pressure Transducer |
0.5 to 4.5 Volts |
0 to 25 Mpa |
| Gas Delivery Pressure |
0.5 to 4.5 Volts |
0 to 690 Kpa Absolute |
| Inlet Manifold Temperature |
0.5 to 4.5 Volts |
-100 to +100 Degrees C |
| Gas Delivery Temperature |
0.5 to 4.5 Volts |
-100 to +100 Degrees C |
| Engine coolant temperature |
0.5 to 4.5 Volts |
0 to 120 Degrees C |
| Drivers demand pedal |
0.5 to 4.5 Volts |
0 to 100% |
| Engine knock |
0.5 to 4.5 Volts |
Knock sensing DSP chip |
| Substitution / Storage switch |
0 to 5V |
Logic level with pull up |
| Record event switch |
0 to 5V |
Logic level with pull up |
| Air conditioning switch |
0 to 5V |
Logic level with pull up |
| Rack Stop Switch |
0 to 5V |
Logic level with pull up |
| |
|
|
| Outputs |
|
|
| Proportional Gas valve |
0V to supply Volts |
10 A 0 to 10 grams per second |
Gas lockoff solenoid on / off |
Supply Voltage |
2 Amps Regulated or HP gas |
| Error LED |
Supply Voltage |
1K Ohm For drivers display |
| Out of gas LED |
Supply Voltage |
1K Ohm For drivers display |
| Spare |
Supply Voltage |
1K Ohm For drivers display |
| “Flowing gas” LED |
0 to Supply Voltage |
External current limit reqd |
| Diesel rack stop stepping motor |
Supply Volts switching 1A Current limit |
2 phase Stepping motor |
| IMAP Throttle control stepping motor |
Supply Volts switching 1A Current limit |
2 phase Stepping motor |
| |
|
|
| Environment |
|
|
| Supply Voltage |
12 or 24 Volts (5 ma
with ignition off) |
Provides power for orderly shut down. |
| Ignition switch input |
12 or 24 Volts |
Provides current to gas valve and shutoff
solenoid |
| Load dump over Voltage protection |
100 Volts Continuous
1000 Volts for 10 us |
|
| Ambient Temperature |
-20 to 50 degrees C |
|
| Protection |
IP 67 |
|
| Mounting Location |
Vehicle body or chassis |
|